Table Top ETO Autoclave
Description
Air replacement:automatic ventilation, cycle ventilation 5 times, interval 15 minutes once
Automatic control system:one button start to end, automatic completion of the whole process
Display:state display temperature, humidity and pressure, sterilization time, processing time, the number of residual gas
Printer:using micro printer, print out the whole process of sterilization each minute of data, can be permanent preservation.
Humidity sensor: built-in humidity sensor automatic detection of cavity humidity, to ensure that the cavity humidity is not less than 45%RH.
Pressure sensor:built-in pressure sensor automatically detects cavity pressure, to ensure the accurate and effective pressure inside the chamber.
Temperature sensor:built-in temperature sensor, automatic detection of cavity temperature, to ensure that the cavity temperature is maintained at 50 degrees C + 3 temperature within the precise range.
Vacuum system:using oil-free vacuum pump, simple and convenient, fast vacuum speed, long service life.
Circulation device:when the water temperature in the heating tank exceeds 85 degrees, the heater should be automatically stopped heating;
Sealed door:anti pressure 200Kpa, EO gas never leak.
Humidifying system:pulse humidification under vacuum condition, ensure the humidity of the cavity is even and controllable; the humidity of the sterilizing room should be controlled within the range of relative humidity of 55% + 20%;
Residual processing device filter on particle diameter of more than 0.3 m the filtering rate of not less than 99.5%.
Sterilization room:Leak rate determination of leakage rate at no-load, sterilization room temperature constant, test pressure -50kPa, time 1H were determined under the conditions of determination of time average leakage rate less than 0.16kPa/min.
Rate:vacuum under no-load condition, atmospheric vacuum sterilizer from time to -60kPa should be less than 30min.
Automatic dosing:the first domestic sterilization chamber piercing technology, to ensure the full use of gas, zero leakage, more safe and reliable.
Heating system:adopts explosion proof electric heating device
A variety of protective functions: with over-voltage, over temperature protection function, more safe and reliable.
Alarm system:With high temperature alarm system, ultra low pressure alarm system
Category:class II medical devices
Technical parameter
Volume (L) |
23L |
Sterilization room size (diameter*depth) cm |
φ24*47 |
Shape dimension (length * width * height) cm |
67×45×40 |
Weight (Kg) |
40 |
Standard sterilization time (min) |
0-99Adjustable hours |
Sterilization temperature(ºC) |
50ºC±3ºC |
Gas selection |
Pure ethylene oxide gas |
Power connection |
220V/50Hz |
Total power(KW) |
1.3 |
Humidity during sterilization |
45%-75% |
Working pressure |
-60kpa |
Single use of ethylene oxide |
30g |