• Pharmaceutical Pure Water Treatment
  • Pharmaceutical Pure Water Treatment
  • Pharmaceutical Pure Water Treatment
  • Pharmaceutical Pure Water Treatment
  • Pharmaceutical Pure Water Treatment
  • Pharmaceutical Pure Water Treatment

Pharmaceutical Pure Water Treatment

Type: Pharmaceutical Water Treatment Equipment
Finished Dosage Form: Liquid
Precision: High Precision
Customization:
Shipping Cost:

Estimated freight per unit.

about shipping cost and estimated delivery time.
Payment Method: visa mastercard discover JCB diners club american express T/T
  Initial Payment Full Payment
Currency: US$
Return&refunds: You can apply for a refund up to 30 days after receipt of the products.
From payment to delivery, we protect your trading.
Pharmaceutical Pure Water Treatment pictures & photos
Pharmaceutical Pure Water Treatment
US $150,000 / Piece
Min. Order: 1 Piece
Diamond Member Since 2018

Suppliers with verified business licenses

Secured Trading Service
Trading Company

Basic Info.

Model NO.
PT-01
Certification
CE, GMP, ISO
Voltage
380V
Computerized
Computerized
Customized
Customized
Condition
New
Warranty
2 Year
After-sales Service
Product Free Warranty Period of One Year (Except M
Transport Package
Wooden Box
Specification
30000&2500&2500
Trademark
medigrade. en. made-in-china. com
Origin
China
HS Code
8401200000
Production Capacity
230000

Packaging & Delivery

Package Size
3000.00cm * 2500.00cm * 2500.00cm
Package Gross Weight
500.000kg

Product Description

60LMechanical batch tank
No. Product Name No. Specification & Model Technical date Unit Qty Brand/Supplier Function Specification
1
Mechanical batch tank
60L (Cylinder material):316L
(Jacket material):304
(Insulation materials):304
(Cylinder thickne):4mm
(Jacket thickne):3mm
(Insulation thickne):3mm
(The design preure of the cylinder): 0.33Mpa(Air preure)
(Jacket design preure):0.33Mpa(Air preure)
(Cylinder design temperature):146ºC                                                                 (Jacket designtemperature):146ºC
(Surface finish): (Mechnical polish)                                                                        (Dimensions):φ700×1500mm
(Insulation materials):(Aluminum silicate fiber mat)
set 1
Medigrade
 

Mixed liquor                                                                                                        
2
Manual diaphragm valve 
DN25 (Body material):316L
(Seal material):PTFE+EPDM
(Connection): (Fast clampo)
(Temp range):(-10~180)ºC
(Preure range):(0~10)bar
set 1 Medigrade
Control the switch of the vent filter
3
Vent filter
5"0.22μm (Filter material):PTFE
9Filter connection 226
(Shell material):316L
9Connection):(Fast clamp)
set 1 Medigrade
Air filtration, to avoid dusts entering into the storage tank.                                
4
Temperature transmitter
PT100 (accuracy):0.5class
(material):316L
(Range):0-200ºC
(Output):4~20mA
(Tension):24VDC
(Connection): (Fast clamp) 
set 1 Medigrade
Test and control WFI temperature                             
5
spray  cleanig ball
DN25 (Material):316L
(Cleaning angle):360°
(Temperature):5-95ºC
(Operating preure):1-2.5bar
(Connection):socket
set 1 Medigrade
Clean the internal tank   
6
Magnetic stirrer
/   (Rotational speed):400R/min
(Power):0.37KW
(Connetion):DIN(flange)
(Motor is full closed ,wind cool)
(Protection grade):IP55 
(Insulated grade):F
 (Voltage):3*380
set 1 Maiteng(SEW motor)
China

Liquid mixed power                                 
7
Frequency converter
/ / (Power):0.75KW
(Frequency):50HZ
(Voltage):3*380
set 1
Danfoss

Speed control                            
8
No neck flange mirror
DN80 (Body material):316L
(Seal material):PTFE+EPDM
(Connection):(flange)
set 1 Medigrade
The interior of the tank were observed
9 Manual tank bottom diaphragm valve DN40 (Body material):316L
(Seal material):PTFE+EPDM
(Connection): (Fast clampo)
(Temp range):(-10~180)ºC
(Preure range):(0~10)bar
set 1 Medigrade
Control of discharge
10 Aseptic sampling valve / DN10 ( Body material):316L
(Connection):(fast clamp)
(Sealing):PTFE
(Max preure):10bar
(Min preure):(Vaccum)
(Available temperature): -10~120ºC
set 1 Medigrade
Detecting liquid meets the requirements
11
Rupture disc                      
/ DN40 (material):316L
(Rupture temp):150ºC±10ºC
(Bursting preure):0.33±0.5%Mpa
(Connection):(Fast clamp)         
set 1 Medigrade
Ensure the normal operation of equipment
12
Preure gauge  
/ (Material):316
(Outside diameter):φ98
(Range):-0.1-0.5MPa
( Connection):(Fast clamp)   
(Accuracy ):1.5 (grade)
( Installation way):(Axial )        
(Connection): (Fast clamp)    
set 1 Medigrade
Display tank preure
13 Weighing Display / IND360 / set 1 Medigrade
Control displays level
14 Weighing module / MMCS 220 set 3 Load cell
15 A horizontal pull rod / MMCS USP set 3 MM S1Stainless steel weigh module top plate transition plate
16 Analog stainle steel junction box / AJB set 1
Signal Confluence
17 Double shielded instrument signal cables / DL-A set 1
Signal transmiion
18
Manual diaphragm valve 
DN25 (Body material):316L
(Seal material):PTFE+EPDM
(Connection): (Fast clampo)
(Temp range):(-10~180)ºC
(Preure range):(0~10)bar
set 1 Medigrade Material inlet
19
Manual diaphragm valve 
DN25 (Body material):316L
(Seal material):PTFE+EPDM
(Connection): (Fast clampo)
(Temp range):(-10~180)ºC
(Preure range):(0~10)bar
set 2 Medigrade CIP inlet > nitrogen inlet.
20 Nitrogen rods DN25 (Material):316   1 Medigrade Nitrogen.
21
Spring full open type safety valve
(Material):QT400-18;
(The pres. Range):0.3-0.7MPa;
(Connection):(Screw).   
set 1
China
Industrial vapor pressure protection.
22 Oiling pressure gauge (Material):304;
(Range):0-1.0MPa;
(Connection):(Screw).
  1 Medigrade Jacket pressure.
23
Temperature transmitter
PT100 (accuracy):0.5class
(material):304
(Range):0-200ºC
(Output):4~20mA
(Tension):24VDC
(Connection): (Fast clamp) 
set 1 Medigrade Jacket temperature.
24 Move the stand (Material):304;
Integrated electric control cabinet;
2 universal wheels with brakes, 2 directional wheels.
set 1 Medigrade  
25 Electric control cabinet Siemens PLC automatic control;
Beijing ZPCON AR3006 paperless recorder;
Temperature control, speed control;
Button start, alarm, emergency stop.
set 1 Medigrade  
150LMechanical batch tank
No. Product Name No. Specification & Model Technical date Unit Qty Brand/Supplier Function Specification
1
Mechanical batch tank
150L (Cylinder material):316L
(Jacket material):304
(Insulation materials):304
(Cylinder thickne):4mm
(Jacket thickne):3mm
(Insulation thickne):3mm
(The design preure of the cylinder): 0.33Mpa(Air preure)
(Jacket design preure):0.33Mpa(Air preure)
(Cylinder design temperature):146ºC
(Jacket designtemperature):146ºC
(Surface finish): (Mechnical polish
(Dimensions):φ900×1800
(Insulation materials):(Aluminum silicate fiber mat)
set 1 Medigrade
Mixed liquor
2
Manual diaphragm valve 
DN40 (Body material):316L
(Seal material):PTFE+EPDM
(Connection): (Fast clampo)
(Temp range):(-10~180)ºC
(Preure range):(0~10)bar
set 1 Medigrade
Control the switch of the vent filter
3
Vent filter
5"0.22μm (Filter material):PTFE
(Filter connection 226
(Shell material):316L
(Connection):(Fast clamp)
set 1 Medigrade
Air filtration, to avoid dusts entering into the storage tank.
4
Temperature transmitter
PT100 (accuracy):0.5class
(material):316L
(Range):0-200ºC
(Output):4~20mA
(Tension):24VDC
(Connection): (Fast clamp) 
set 1 Medigrade
Test and control WFI temperature 
5
spray
DN25 (Material):316L
(Cleaning angle):360°
(Temperature):5-95ºC
(Operating preure):1-2.5bar
(Connection):socket
set 1 Medigrade
Clean the internal tank 
6
Magnetic stirrer
/   (Rotational speed):400R/min
(Power):0.37KW
(Connetion):DIN(flange)
(Motor is full closed ,wind cool) (Protection grade):IP55(Insulated grade):F
(Voltage):3*380
set 1 Medigrade
Liquid mixed power 
7 Frequency converter / / (Power):0.75KW
(Frequency):50HZ
(Voltage):3*380
set 1 Medigrade
Speed control
8 No neck flange mirror DN50 (Body material):316L
(Seal material):PTFE+EPDM
(Connection):(flange)
set 1 Medigrade
The interior of the tank were observed
9 Manual tank bottom diaphragm valve DN40 (Body material):316L
(Seal material):PTFE+EPDM
(Connection): (Fast clampo)
(Temp range):(-10~180)ºC
(Preure range):(0~10)bar
set 1 Medigrade
Control of discharge
10 Aseptic sampling valve / DN10 ( Body material):316L
(Connection):(fast clamp)
(Sealing):PTFE
(Max preure):10bar
(Min preure):(Vaccum)
(Available temperature): -10~120ºC
set 1 Medigrade
Detecting liquid meets the requirements
11
Rupture disc
DN40 (material):316L
(Rupture temp):150ºC±10ºC
(Bursting preure):0.33±0.5%Mpa
(Connection):(Fast clamp) 
  1 Medigrade
Ensure the normal operation of equipment
12
Preure gauge
DN40 (Material):316
(Outside diameter):φ98
(Range):-0.1-0.5MPa
( Connection):(Fast clamp)
(Accuracy ):1.5 (grade)
( Installation way):(Axial )
(Connection): (Fast clamp)
set 1 Medigrade
Display tank preure
13 Weighing Display / IND331 set 1 Medigrade Control displays level
14 Weighing module / MMS1 550 set 3 Load cell
15 A horizontal pull rod / MMS1 USP set 3 MM S1Stainless steel weigh module top plate transition plate
16 Analog stainle steel junction box / AJB set 1 Signal Confluence
17 Double shielded instrument signal cables / DL-A set 1 Signal transmiion
18
Manual diaphragm valve 
DN25 (Body material):316L
(Seal material):PTFE+EPDM
(Connection): (Fast clampo)
(Temp range):(-10~180)ºC
(Preure range):(0~10)bar
set 1 Medigrade Material inlet
19
Manual diaphragm valve 
DN40 (Body material):3(Seal material):PTFE+EPDM
(Connection): (Fast clampo)
(Temp range):(-10~180)ºC
(Preure range):(0~10)bar
set 2 Medigrade CIP inlet > nitrogen inlet.
20 Nitrogen rods DN25 (Material):316   1 Medigrade Nitrogen.
21
Spring full open type safety valve
(Material):QT400-18;
(The pres. Range):0.3-0.7MPa;
(Connection):(Screw). 
set 1 Medigrade Industrial vapor pressure protection.
22 Oiling pressure gauge (Material):304;
(Range):0-1.0MPa;
(Connection):(Screw).
  1 Medigrade Jacket pressure.
23
Temperature transmitter
PT100 (accuracy):0.5class
(material):304
(Range):0-200ºC
(Output):4~20mA
(Tension):24VDC
(Connection): (Fast clamp) 
set 1 Medigrade Jacket temperature.
24 Move the stand (Material):304;
Integrated electric control cabinet;
2 universal wheels with brakes, 2 directional wheels.
set 1 Medigrade  
25 Electric control cabinet Siemens PLC automatic control;
Beijing ZPCON AR3006 paperless recorder;
Temperature control, speed control;
Button start, alarm, emergency stop.
set 1 Medigrade  

300LMechanical batch tank
No. Product Name
No.
Specification & Model Technical date Unit Qty Brand/Supplier Function Specification
1
Mechanical batch tank
300L (Cylinder material):316L
(Jacket material):304
(Insulation materials):304
(Cylinder thickness):4mm
(Jacket thickness):3mm
(Insulation thickness):3mm
(The design pressure of the cylinder):0.33Mpa(Air pressure)
(Jacket design pressure):0.33Mpa(Air pressure)
(Cylinder design temperature):146ºC
(Jacket design temperature):146ºC
(Surface finish): (Mechnical polish)
(Dimensions): φ900×1600
(Insulation materials):(Aluminum silicate fiber mat)
set 1 Medigrade
Mixed liquor
2
Manual diaphragm valve 
DN40 (Body material):SS316L
(Seal material):PTFE+EPDM
(Connection): (Fast clampo)
(Temp range):(-10~180)ºC
(Pressure range):(0~10)bar
set 1 Medigrade
Control the switch of the vent filter
3
Vent filter
5"0.22μm (Filter material):PTFE
(Filter connection 226
(Shell material):SS316L
(Connection):(Fast clamp) 
set 1 Medigrade
Air filtration, to avoid dusts entering into the storage tank.
4 Temperature transmitter PT100 (accuracy):0.5class
(material):SS316L
(Range):0-200ºC
(Output):4~20mA
(Tension):24VDC
(Connection): (Fast clamp) 
set 1 Medigrade
Test and control WFI temperature 
5
spray cleanig ball
DN25 (Material):SS316L
(Cleaning angle):360°
(Temperature):5-95ºC
(Operating pressure): 1-2.5bar
(Connection): socket
set 1 Medigrade
Clean the internal tank 
6
Magnetic stirrer
/ / (Rotational speed):400R/min
(Power):0.37KW
(Connetion):DIN(flange)
(Motor is full closed ,wind cool)
(Protection grade):IP55
(Insulated grade):F
(Voltage):3*380
set 1 Medigrade
Liquid mixed power 
7
Frequency converter
/ / (Power):0.75KW
(Frequency):50HZ
(Voltage):3*380
set 1 Medigrade Speed control
8
No neck flange mirror
DN80 (Body material):SS316L
(Seal material):PTFE+EPDM
(Connection):(flange)
set 1 Medigrade
The interior of the tank were observed
9 Manual tank bottom diaphragm valve DN40 (Body material):SS316L
(Seal material):PTFE+EPDM
(Connection): (Fast clampo
(Temp range):(-10~180)ºC
(Pressure range):(0~10)bar
set 1 Medigrade Control of discharge
10 Aseptic sampling valve / DN10 ( Body material):SS316L
(Connection):(fast clamp)
(Sealing):PTFE
(Max pressure):10bar(Min pressure):(Vaccum)
(Available temperature): -10~120ºC
set 1 Medigrade Detecting liquid meets the requirements
11
Rupture disc
/ DN40 (material):SS316L
(Rupture temp):150ºC±10ºC
(Bursting pressure):0.33±0.5%Mpa
(Connection):(Fast clamp) 
  1 Medigrade
Ensure the normal operation of equipment
12
Pressure gauge
DN40 (Material):SS316
(Outside diameter):φ98
(Range):-0.1-0.5MPa
( Connection):(Fast clamp)
(Accuracy ):1.5 (grade)
( Installation way):(Axial )
(Connection): (Fast clamp)
set 1 Medigrade
Display tank pressure
13 Weighing Display / IND331 set 1 Medigrade Control displays level
14 Weighing module / MM SS S1 550 set 3 Load cell
15 A horizontal pull rod / MM SS S1 USP set 3 MM S1Stainless steel weigh module top plate transition plate
16 Analog stainless steel junction box / AJB set 1 Signal Confluence
17 Double shielded instrument signal cables / DL-A set 1 Signal transmission
18
Manual diaphragm valve 
DN25 (Body material):316L
(Seal material):PTFE+EPDM
(Connection): (Fast clampo)
(Temp range):(-10~180)ºC
(Preure range):(0~10)bar
set 1 Medigrade Material inlet
19
Manual diaphragm valve 
DN40 (Body material):316L
(Seal material):PTFE+EPDM
(Connection): (Fast clampo)
9Temp range):(-10~180)ºC
9Preure range):(0~10)bar
set 2 Medigrade CIP inlet > nitrogen inlet.
20 Nitrogen rods DN25 (Material):316   1 Medigrade Nitrogen.
21
Spring full open type safety valve
(Material):QT400-18;
(The pres. Range):0.3-0.7MPa;
(Connection):(Screw). 
set 1 Medigrade Industrial vapor pressure protection.
22 Oiling pressure gauge (Material):304;
(Range):0-1.0MPa;
(Connection):(Screw).
  1 Medigrade Jacket pressure.
23
Temperature transmitter
PT100 (accuracy):0.5
(material):304
(Range):0-200ºC
(Output):4~20mA
(Tension):24VDC
9Connection): (Fast clamp) 
set 1 Medigrade Jacket temperature.
24 Move the stand 9Material):304;
Integrated electric control cabinet;
2 universal wheels with brakes, 2 directional wheels.
set 1 Medigrade  
25 Electric control cabinet Siemens PLC automatic control;
Beijing ZPCON AR3006 paperless recorder;
Temperature control, speed control;
Button start, alarm, emergency stop.
set 1 Medigrade  

Send your message to this supplier

*From:
*To:
*Message:

Enter between 20 to 4,000 characters.

This is not what you are looking for? Post a Sourcing Request Now