Pulse&Vacuum High Pressure Sterilizer

Product Details
Customization: Available
Theory: Pressure Steam
Type: Pressure Steam Sterilization Equipments
Diamond Member Since 2018

Suppliers with verified business licenses

Audited Supplier

Audited by an independent third-party inspection agency

Type of Ownership
Limited Company
Management System Certification
ISO 9001, ISO 9000, GMP, ISO 13485
  • Pulse&Vacuum High Pressure Sterilizer
  • Pulse&Vacuum High Pressure Sterilizer
  • Pulse&Vacuum High Pressure Sterilizer
  • Pulse&Vacuum High Pressure Sterilizer
Find Similar Products

Basic Info.

Model NO.
MD
Certification
CE
Electric Tension
220V/380V
LCD Display
With LCD Display
Ultra High Temperature Alarm
Ultra High Temperature Alarm
Sterilization Information Recording and Printing
Sterilization Information Recording and Printing
Material
Carbon Steel
Model Type
Vertical
Heating Method
Electric
Power
10.0kw
Carton Size
1150X770X1520mm
Chamber Size
420×700mm
Temperature Display
LCD
Designed Pressure
0.29MPa
Rated Working Pressure
0.21MPa
Designed Temperature
121ºC/134ºC
Pulse Times
0-99
Sterilize Time
0-9999 Seconds
Drying Time
0-9999 Seconds
Chamber Safety Valve
Open>=0.23MPa, Close<=0.21MPa
Pulse Anelitude Value
Positive Value 0.06gative Value -0.
Generator Water Source
Soften Water or Purify Water
Transport Package
Wooden Packing
Specification
263kg
Trademark
Medigrade
Origin
Shanghai, China
HS Code
841920000
Production Capacity
25 Sets/Year

Product Description

Pulse&Vacuum Type High Pressure Autoclave
Pulse&Vacuum High Pressure Sterilizer

Specification
Model SQ-Z12 SQ-Z60
Volume 100L 200L
Type Vertical Vertical
Heating method Electric Electric
Power 10.0KW 20.0KW
Power supply AC380V,50Hz AC380V,50Hz
Carton size 1150x770x1520mm 1190x810x1580mm
Chamber size 420×700mm 500×1000mm
Net weight 263kg 305kg
Temperature display LCD LCD
Designed pressure 0.29MPa 0.29MPa
Rated working pressure 0.21Mpa; 0.21Mpa
Designed temperature 121ºC/134ºC 121ºC/134ºC
Pulse times 0~99 0~99
Sterilize time 0~9999 seconds 0~9999 seconds
Drying time 0~9999 seconds 0~9999 seconds

Chamber safety valve:open>=0.23Mpa,close<=0.21Mpa;
Pulse amplitude value:positive value 0.065Mpa~0.09Mpa,negative value -0.06Mpa~-0.08Mpa
Pressure controller set:up switch value 0.23Mpa, down switch value 0.21Mpa
Generator water source:soften water or purify water, the water temperature ≤45ºC,water pressure 0~0.05 Mpa.
Vacuum pump water source:running water(should not be too hard), water pressure 0.10Mpa~0.20Mpa
Air output:more than 99% (pulse more than 3 times)
Vacuum drying:avoid the sterilized item wet after sterilization. 
Pulse exhaust:Positive pressure dynamic pulse exhaust, eliminate the chamber indoor cold air completely, to ensure that the steam saturation
Procedures:Equipped with liquid, culture medium sterilize thermal insulation, culture medium dissolved insulation, glass, utensils, rubber, a variety of procedures to choose.
Microcomputer control technology
The sterilizer using intelligent control of the microprocessor, man-made interface, easy to operate, safe and reliable. The parameters and status of the process are displayed dynamically through the digital screen. Vacuum, water injection, heat up, sterilization, pressure relief, exhaust, dry, power off automatically; equipment abnormal work automatically detect and alarm; fault automatic diagnosis, over-temperature, over-pressure automatic protection to ensure the reliability of sterilization. After the sterilization is complete, the buzzer automatically prompts that the ED display is complete.
Locking device
Before the sterilization cycle is started, the interlock is unlocked when the door is closed, and the door can be closed and turned on repeatedly. Only the door closed in place, the sterilizer can start running, in the course of the sterilizer door should not open. After the start of the cycle operation, if the failure and fault indication, the sterilization room is not fully released, interlock device should be locked, the sterilizer door should not open.
Pulsation mode:Microcomputer control according to site conditions automatically select the number of pulse to ensure the coordination of temperature and pressure.
Vacuum:Three times pre-vacuum, to ensure heating more faster, sterilization more thoroughly.
Safety valve:When the sterilizer pressure reaches 240kPa ± 5kPa, the safety valve automatically open to relief the pressure.
Over pressure protection procedure:When the sterilization chamber pressure reaches 220 ± 5kPakPa, there is a tone and can automatically pressure relief.
Air Leakage:When the sterilizer is tested at each stage, the pressure rise rate should not be greater than 0.13kPa / min.
Sterilization chamber dynamic pressure:The pressure change during any 2s interval during the sterilizer cycle should not exceed 1000 kPa / min.
Vacuum pump:Using a bowl of oil-free vacuum pump, simple and convenient, fast vacuum rate, long service life. To ensure that the vacuum can reach-80kpa;
Pressure sensor:Built-in pressure sensor automatically detects the pressure inside the chamber to ensure accurate and effective pressure inside the cavity.
Temperature sensor:Built-in temperature sensor automatically detects the temperature inside the cavity to ensure that the cavity to maintain the use of temperature within ± 3 ºC within the precise range.
Sterilization mode:Were bare equipment, cotton yarn, parcel, plastic and rubber products, the default operating temperature of 135 ºC.
Automatic drying:Strong vacuum drying, for different items dry demand; equipment residual humidity<0.2%.
Steam inside the row:Built-in condensate collector, waste steam will be exclusion after condensed by the condenser, not outside the row of waste steam, more safe and clean.
Seal structure:Seal ring for the silicone products, design life of 2 years (1200 times) is not aging is not deformed.
Casters:Yes
Alarm system:With a high and low temperature alarm system
Category:Class B medical equipment


If you are interested in this, please contact me: Nana Zhang
Shanghai Medigrade Industry Co.,Ltd
Waigaoqiao Free Trade Zone, Shanghai,China
Cell Phone: 0086-15800947006
Tel: 0086-21-58589972
Fax: 0086-21-68689726
medigrade.en.made-in-china.com

Send your message to this supplier

*From:
*To:
*Message:

Enter between 20 to 4,000 characters.

This is not what you are looking for? Post a Sourcing Request Now
Contact Supplier
Product Groups
More